Metal protective coatings
AcUrShld D215 High-Build Acrylic Polyurethane Topcoat
For steelwork or outdoor equipment enquiries seeking a high-build finishing option.
AcUrShld D215 · Finish layer
- AcUrShld D215 · Finish coat
- Intermediate coat
- Primer
- Prepared steel plate
Key specifications
| Product role | High-build topcoat |
|---|---|
| Chemistry | Acrylic polyurethane |
| Components | Two components (2K) |
| Dry film thickness | 70–100 µm per coat. |
| Theoretical coverage | 6.5–9.3 m²/L at the stated DFT, before thinning and site losses. |
| Mix ratio A:B | 4:1 by weight |
| Colour | Standard / RAL on request |
| Finish | Gloss ≥80 GU at 60° |
| Volume solids | 65.0% by volume (63.0%–67.0%) |
| Mass solids | 78.0% by weight (76.0%–80.0%) |
| Density | 1.340 kg/L at 25 °C, mixed A+B before thinning |
Additional engineering and product references
- VOC content
- <420 g/L
- Wet film thickness
- 108–154 µm per coat before thinning.
TDS & SDS
TDS Technical data sheet
A Component SDS
B Component SDS
Coating system
State target film build and the coats below, and confirm the actual application requirements.
- Confirm sag control, drying and final appearance at the intended film thickness.
For structural steel: compare atmospheric exposure categories C1–C5
Substrate preparation
Identify the specified underlying coat. Confirm it is clean, sound and ready for recoating under the applicable instructions. Other substrates or an unidentified coating need project-specific confirmation.
For structural steel, use these checks:
Application reference
| Application method | Airless / conventional spray |
|---|---|
| Application temperature | 5–35 °C |
| Relative humidity | ≤85% |
| Mix ratio A:B | 4:1 by weight |
| Pot life | Engineering working time: maximum 2 h at 25 °C. Start timing when A and B are first combined; induction and application are included. Discard material when this time expires or when application viscosity rises, whichever occurs first. |
| Touch dry | 1 h at 25 °C and 50% RH under the adopted engineering application condition. |
| Dry to handle | Allow 9 h at 25 °C and 50% RH before handling. |
| Recoat interval | 8–72 h at 25 °C and 50% RH; clean and abrade after the maximum. |
| Full cure | 7 days at 25 °C and 50% RH. |
| Thinner | UreThi 10 |
| Thinning reference | Use UreThi 10, 0–10% by volume of the mixed coating, for all permitted methods. Thinner supply density: ≤1.00 kg/L at 25 °C. |
Packaging & ordering
| Packaging | Use the product-specific matched kit listed under Component packaging. Identify the net mass of each component on its label. |
|---|---|
| Matched component set | A 16 kg + B 4 kg / 20 kg set |
| Shelf life | 12 months |
Include the quantity, delivery country and colour reference in your enquiry.