Industrial floor coatings
FloPri SB11 2K solvent-based penetrating epoxy primer
A penetrating primer for sound, dry concrete and cementitious screeds. It is not a moisture barrier.
FloPri SB11 · Primer
- FloPri SB11 · Primer
Key specifications
| Product role | Penetrating primer |
|---|---|
| Chemistry | Solvent-based epoxy |
| Components | Two components (2K) |
| Consumption | 0.10–0.15 kg/m² A+B per coat for penetration; repeat on absorbent areas until uniformly sealed. |
| Mixed density | 1.100 kg/L at 25 °C, mixed A+B before thinning |
| Mass solids | 80.0% by weight (78.0%–82.0%) |
| Volume solids | 75.0% by volume (72.0%–79.0%) |
| VOC content | <400 g/L |
| Suitable substrate / previous layer | Sound, dry concrete and cementitious screeds |
TDS & SDS
TDS Technical data sheet
A Component SDS
B Component SDS
Coating system
| Recommended coating system | FloPri SB11; compatible FloMor SB10/SB12 or SF22 as required; selected FloTop finish; verify intercoat adhesion. |
|---|
Substrate preparation
Verify the substrate condition, moisture and previous coating where present. Follow the preparation instructions for the specified system.
Application reference
| Mix ratio (A:B) | 1:1 by weight |
|---|---|
| Pot life | Approx. 40 min at 25 °C |
| Touch dry | Approx. 2 h at 25 °C |
| Hard dry | Approx. 8 h at 25 °C |
| Full cure | Approx. 7 days at 25 °C |
| Recoat interval | 8 h–48 h at 25 °C; abrade and clean if exceeded. |
| Ambient temperature | 10–35 °C |
| Substrate temperature | 10–35 °C |
| Relative humidity | ≤80% |
| Thinning / dilution | EpoThi 10 floor-coating grade: 0–5% by weight of fully mixed A+B. |
| Dedicated hardener | FloPri SB11 Part B. Use the matched kit at the stated product-specific A:B weight ratio. |
Packaging & ordering
| Component packaging | Part A: 15 kg; Part B: 15 kg |
|---|---|
| Complete pack | 30 kg per set |
| Shelf life | 12 months in unopened original packs. |
| Storage temperature | 5–30 °C; dry, sealed, protected from sunlight; keep away from ignition sources. |